Availability: Sorry, this item has been DISCONTINUED.
Price: $134.97 $209.97
You Save: $75.00

Manuals

First Alert Wireless Interconnect Battery Operated Smoke Alarm


First Alert's series of Wireless Battery Operated Smoke Alarms effectively eliminates the need for a wired connection and operates entirely on batteries. The latest advancement in a series celebrated for its intuitive use of technology, the First Alert Wireless Interconnect collection offers an abundance of options when it comes to creating the ideal safety network. Wireless inter-connectivity allows you to connect up to 16 First Alert Wireless Interconnect alarms within your home! Should one Wireless Interconnect alarm sound off, the remainder of your Wireless Interconnected alarms will also trigger simultaneously and alert you and your home to any potential dangers. This feature allows for the maximum in whole home protection.

The realization of Photoelectric Smoke Sensing Technology will effectively reduce the number of nuisance alarms triggered by cooking smoke and shower steam. This alarm comes equipped with a Mute Button that serves the dual purpose of quickly silencing your alarm as well as testing its function. First Alert Wireless Interconnect Battery Operated Smoke Alarms also come equipped with an EZ access battery door that removes the hassle and burden of collecting your alarm from the ceiling and replacing its batteries. The combination of an optional theft-prevention lock and an increased emphasis on the unit's 85db sound output establish peace of mind, while the inclusion of an anti-theft prevention lock all but guarantees the safest of experiences. This alarm comes with a 10-year limited warranty and meets UL Standards.

This Wireless Interconnect alarm is for you if:
  • You want to build a safety network of interconnected alarms in your home without the cost and hassle of wiring.
  • You want an instructional DVD on the benefits of First Alert Wireless Interconnect Products.
Where To Place Smoke Alarms: One on every level of the home and one in each sleeping area.

This product is intended for non-professional do it yourself installation. If you would like information about a professionally installed and monitored system, please contact First Alert Professional at 1-800-921-6025. First Alert Professional is not affiliated with BRK Brands, Inc.
What is a mesh network and how do the First Alert Wireless Interconnect smoke detectors intercommunicate?
First Alert Wireless Interconnect smoke alarms operate on a "mesh network" to integrate smoke alarms for better safety and response in an emergency. All of the First Alert Wireless Interconnect alarms send, receive and resend the initiating alarm's signal. Why is this important? Let's say the signal is blocked from reaching the master bedroom alarm either by distance or some obstruction in the home. With First Alert Wireless Interconnect, the mesh network of alarms re-routes and re-sends the signal via the other alarms, providing a greater chance all alarms will receive the signal. The "mesh network" is a more reliable means of wireless communication.
What is the proper placement of smoke alarms?
It is important that you have the proper placement for your smoke alarms. Install your alarms at least 20 feet from appliances like furnaces and ovens, which produce combustion particles. Alarms should be at least 10 feet from high humidity areas like showers and laundry rooms, and at least 3 feet from heat/AC vents. Be sure to install a smoke alarm in each bedroom, one at the top of each stairwell, and one on every level.
My smoke alarm keeps chirping and beeping. Why does my smoke alarm chirp intermittently?
It is likely that the reason your smoke alarm keeps chirping and beeping is that the battery is low. Whenever your smoke alarm keeps chirping, replace the battery immediately.

Other reasons include: It could be a different device or appliance such as a security system, monitor, carbon monoxide alarm, or other device which has a similar low battery or alert signal. Some of the same factors that cause unwanted alarms can cause intermittent alarms: dust and insects in the alarm or power interruptions in hardwired alarms. Improper wiring on AC or AC/DC smoke alarms. AC alarms will chirp every 5 seconds if the interconnect wire is grounded. The orange interconnect wire should NEVER be grounded; it should only be used to interconnect other smoke alarms or compatible devices.

Why doesn't my smoke alarm sound when I push the test button?
It is important that you frequently test your smoke alarms. When you are testing your smoke alarm, there are a number of reasons why the alarm might not sound:
  • You may not be holding the test button down long enough. Try holding it down for up to 10 seconds (20 seconds on photoelectric models) .
  • Your battery may not be installed properly or snapped all the way in place. Even if the alarm sounded briefly when the battery touched the terminals, you still need to make sure it is snapped securely in place. If the battery is loose, in cannot power the smoke alarm properly. After installing new batteries, be sure to test your smoke detector.
  • Your AC power may not be on. AC and AC/DC units will have a power indicator light (red or green) that shines continuously when they are receiving electrical power.
  • If you have a 10-Year model, the smoke alarm may not have been properly activated. If the tab broke away before the alarm was activated, you can use a toothpick to move the switch over to test the alarm.
Why does my smoke alarm go off when I install a battery or turn on the AC power?
It is normal for smoke alarms to go off and sound briefly (up to 5-10 seconds) when you install a new battery or when they are powered up. If the alarm continues to go off and no smoke is present, the cause may be one of the following:
  • There may be insufficient battery power, try new batteries.
  • Problems with voltage or insufficient electrical power (brown out) may cause a continuous weak sounding alarm. For AC or AC/DC models, temporarily disconnect power at the service panel until the brown out is over. If you do not restore the AC power, your smoke alarms cannot warn you of a fire.
  • Incompatible warning device. If an incompatible alarm or auxiliary device is linked into a series of AC or AC/DC smoke alarms it may cause the system inadvertently go off.
My smoke alarm keeps chirping, even with a new battery. What is causing this?
There are a number of possible causes for your smoke alarm to keep chirping even with a new battery.
  • It is possible that your smoke alarm "silence" button was pushed by mistake. The alarm will now "chirp" once a minute for up to 15 minutes before resetting.
  • Are you sure it's the smoke alarm? Funny to ask, but other devices have similar low battery chirps or warning tones.
  • Your "new" batteries may not be fresh. If batteries are stored, especially in cold areas like refrigerators, they lose their charge more quickly. Always check the freshness date on the package when buying new batteries. Keep plenty of replacement batteries on hand so that you are sure to always be protected by your smoke alarms.
I lost my First Alert smoke alarm owner's manual. How can I get a new one?
First Alert smoke alarm owner's manuals are available online for download at no cost. Find your alarm in our Smoke Alarms section.
Why does the National Fire Protection Association (NFPA) recommend that home smoke alarms be replaced after 10 years?
Smoke alarms have a limited life. Although each smoke alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail over time. Therefore, you must test the devices weekly. The unit should be replaced immediately if it is not operating properly. The performance of smoke alarms older than 10 years is simply not reliable. To ensure your family's safety, all carbon monoxide and smoke/CO combination alarms need to be replaced every 5-7 years. All smoke alarms need to be replaced every 10 years.

If it's time to replace your alarms, consider the NEW 10-Year Life series and never have to worry about a battery replacement for the life of the alarm.10-Year alarms are available in smoke, carbon monoxide and combination alarms.

I'm ready to change my alarm battery - what replacement batteries can I use?
Check your User's Manual or the nameplate on the back of the alarm. Different smoke detectors & CO alarms use different kinds of batteries - 9V, AA, AAA - it all depends on the particular model you have. Use quality batteries like lithium batteries - having plenty of power is worth any extra cost. Never use rechargeable batteries because they may not always provide a consistent charge.
Product Details

First Alert Wireless Interconnect Battery Operated Smoke Alarm Features:

  • Wireless inter-connectivity, connect up to 18 First Alert Wireless Interconnect alarms in your home and when one sounds, they all sound for increased whole-home protection.
  • Photoelectric smoke sensing, optimal protection from smoldering fires. plus, reduces false alarms like those caused by cooking fires and shower steam.
  • Mute button, mutes unnecessary alarms immediately. also tests alarm function with same button.
  • Eco-friendly, completely recyclable as an electronic device.
  • Bonus educational & training DVD included.
  • EZ access battery door, no need to remove alarm from ceiling to change battery.
  • Optional theft-prevention lock, when activated, batteries and/or alarm cannot be removed without proper tools.
  • 2AA batteries included.
  • Loud 85db alarm.
  • 10-year limited warranty, smoke alarms should be replaced every 10 years for maximum protection.
  • Meets UL217 standard.
  • FCC compliant.
  • Product Specs
    UPC:
    111012340005
    MPN:
    SA501CN-3ST
    Category:
    Wireless Interconnect Alarms
    Product Manuals

    If you are interested in ordering a large quantity of items you may qualify for volume pricing discounts. Volume Discount Pricing is a great way for customers to save big on large, bulk orders of most items available in our store. Please send a bulk order request to our friendly sales staff so they may create a quote and provide personal service for your order! You will receive a response within 1-2 business days and our office hours are Monday through Friday, 8am-5pm CST.

    We make it as easy as possible to ensure you get the lowest prices available:
    • Let us know what products & the quantities you are interested in.
    • Get a detailed quote from a dedicated sales rep.
    • Our warehouse ships directly to you.
    • You enjoy the savings & are now a preferred customer.
    Send A Request Now
    Direct From Warehouse Pricing bulk purchase, wholesale pricing
    SA501CN-3ST customer reviews

    Overall Rating

    4.9
    19 Reviews
    5
    17
    4
    2
    3
    0
    2
    0
    1
    0
    19 customers recommend this product
    First Alert Wireless Interconnect Battery Operated Smoke Alarm Reviews
    Jaime Cabot
    February 16, 2017
    Why was First Alert One Link Battery operated wireless discontinued

    Product works great easy to install and works when power goes out something I need in a smoke/CO detector. Need to add another unit but can no longer find the units.

    Charles Hinton
    December 16, 2016
    Verified Purchase
    Used this over 10 times now

    Works everytime

    Barbara Clark
    December 5, 2016
    Verified Purchase

    I am very satisfied with the performance of this product. It works very well.

    Charles Hinton
    April 25, 2016
    Verified Purchase
    Always Works perfect

    Always Works perfect

    Todd Magnani
    February 24, 2016
    Verified Purchase

    Very easy to install.

    Thomas Weber
    February 12, 2016
    Verified Purchase
    Easy to install, works great

    Smoke detector SA501CN-3ST. Installed 3 of these smoke detectors on 3 different levels of my home. There were metal ducts in the vicinity. All 3 detectors communicate fine, and all 3 alarm when any are tested. I wanted to be able to hear alarms from anywhere in my home, and these detectors make that possible.

    James McAllister
    January 27, 2016
    Verified Purchase

    Product arrived on time and in good shape. Instructions were easy to follow and product works well. Thanks.

    Kathleen Russell
    March 3, 2015
    Verified Purchase
    Excellent smoke and carbon monoxide detectors

    It only took a little time to set up the smoke and carbon monoxide detectors and they are excellent and all work together extremely well.

    Patricia Shewmake
    July 13, 2014
    Verified Purchase

    Great

    Patricia Shewmake
    November 20, 2013
    Verified Purchase

    Al products on this order are great. We use them all the time.

    0 $0.00
    Top