Diane Taylor
January 23, 2019
Verified Purchase

Great product....only one I will purchase

Charles Jester
April 16, 2018
Verified Purchase
Inconspicuous

Thin units escape notice. Good value, great warranty, easy to install.

Stephen Byron
August 22, 2017
Verified Purchase
Easy to mount, looks good !

This new slim alarm was easy to mount and looks good. I highly recommend anyone looking for an alarm to consider it. I will be placing another order in the near future for the combination smoke/carbon monoxide alarm!

Leanne BK
April 10, 2017
Verified Purchase
Great product

We bought this product because First Alert carries many options for photoelectric smoke alarms, which are recommended. We love the low profile.

Patricia  Sharar
October 4, 2016
Verified Purchase

I have used First Alert Alarms in this house for so long. It is hard to believe we have been here for 21 years. I lose track of time. Guess I am getting old. haha Thank You

Thomas Reston
June 26, 2013
Simple

I ordered this alarm after seeing the feature on Photo vs Ion sensing technology on the Today show. This alarm meets those requirements and was really easy to install.

How often do you need to change the batteries?
Actual battery service life depends on the particular design of your smoke or carbon monoxide alarm and the environment in which it is installed. All kinds of alarm batteries specified in the user's manual are acceptable replacement batteries. Regardless of the manufacturer's suggested battery life, you MUST replace the batteries immediately once the unit starts "chirping" (the "low battery warning"). It is recommended that you change the batteries in your alarms when you change your clocks for daylight saving time. Also consider replacing your current alarms with 10-Year Life Alarms that never require a costly battery replacement for the ten year life of the alarm. This 10-Year series is available in smoke, carbon monoxide and combination alarms.

What is the proper placement of smoke alarms?
It is important that you have the proper placement for your smoke alarms. Install your alarms at least 20 feet from appliances like furnaces and ovens, which produce combustion particles. Alarms should be at least 10 feet from high humidity areas like showers and laundry rooms, and at least 3 feet from heat/AC vents. Be sure to install a smoke alarm in each bedroom, one at the top of each stairwell, and one on every level.
My smoke alarm keeps chirping and beeping. Why does my smoke alarm chirp intermittently?
It is likely that the reason your smoke alarm keeps chirping and beeping is that the battery is low. Whenever your smoke alarm keeps chirping, replace the battery immediately.

Other reasons include: It could be a different device or appliance such as a security system, monitor, carbon monoxide alarm, or other device which has a similar low battery or alert signal. Some of the same factors that cause unwanted alarms can cause intermittent alarms: dust and insects in the alarm or power interruptions in hardwired alarms. Improper wiring on AC or AC/DC smoke alarms. AC alarms will chirp every 5 seconds if the interconnect wire is grounded. The orange interconnect wire should NEVER be grounded; it should only be used to interconnect other smoke alarms or compatible devices.

Why doesn't my smoke alarm sound when I push the test button?
It is important that you frequently test your smoke alarms. When you are testing your smoke alarm, there are a number of reasons why the alarm might not sound:
  • You may not be holding the test button down long enough. Try holding it down for up to 10 seconds (20 seconds on photoelectric models) .
  • Your battery may not be installed properly or snapped all the way in place. Even if the alarm sounded briefly when the battery touched the terminals, you still need to make sure it is snapped securely in place. If the battery is loose, in cannot power the smoke alarm properly. After installing new batteries, be sure to test your smoke detector.
  • Your AC power may not be on. AC and AC/DC units will have a power indicator light (red or green) that shines continuously when they are receiving electrical power.
  • If you have a 10-Year model, the smoke alarm may not have been properly activated. If the tab broke away before the alarm was activated, you can use a toothpick to move the switch over to test the alarm.
Why does my smoke alarm go off when I install a battery or turn on the AC power?
It is normal for smoke alarms to go off and sound briefly (up to 5-10 seconds) when you install a new battery or when they are powered up. If the alarm continues to go off and no smoke is present, the cause may be one of the following:
  • There may be insufficient battery power, try new batteries.
  • Problems with voltage or insufficient electrical power (brown out) may cause a continuous weak sounding alarm. For AC or AC/DC models, temporarily disconnect power at the service panel until the brown out is over. If you do not restore the AC power, your smoke alarms cannot warn you of a fire.
  • Incompatible warning device. If an incompatible alarm or auxiliary device is linked into a series of AC or AC/DC smoke alarms it may cause the system inadvertently go off.
My smoke alarm keeps chirping, even with a new battery. What is causing this?
There are a number of possible causes for your smoke alarm to keep chirping even with a new battery.
  • It is possible that your smoke alarm "silence" button was pushed by mistake. The alarm will now "chirp" once a minute for up to 15 minutes before resetting.
  • Are you sure it's the smoke alarm? Funny to ask, but other devices have similar low battery chirps or warning tones.
  • Your "new" batteries may not be fresh. If batteries are stored, especially in cold areas like refrigerators, they lose their charge more quickly. Always check the freshness date on the package when buying new batteries. Keep plenty of replacement batteries on hand so that you are sure to always be protected by your smoke alarms.
I lost my First Alert smoke alarm owner's manual. How can I get a new one?
First Alert smoke alarm owner's manuals are available online for download at no cost. Find your alarm in our Smoke Alarms section.
Why does the National Fire Protection Association (NFPA) recommend that home smoke alarms be replaced after 10 years?
Smoke alarms have a limited life. Although each smoke alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail over time. Therefore, you must test the devices weekly. The unit should be replaced immediately if it is not operating properly. The performance of smoke alarms older than 10 years is simply not reliable. To ensure your family's safety, all carbon monoxide and smoke/CO combination alarms need to be replaced every 5-7 years. All smoke alarms need to be replaced every 10 years.

If it's time to replace your alarms, consider the NEW 10-Year Life series and never have to worry about a battery replacement for the life of the alarm.10-Year alarms are available in smoke, carbon monoxide and combination alarms.

What does the flashing red light mean?
The red light flashes to show that the CO Alarm is receiving battery power.
I'm ready to change my alarm battery - what replacement batteries can I use?
Check your User's Manual or the nameplate on the back of the alarm. Different smoke detectors & CO alarms use different kinds of batteries - 9V, AA, AAA - it all depends on the particular model you have. Use quality batteries like lithium batteries - having plenty of power is worth any extra cost. Never use rechargeable batteries because they may not always provide a consistent charge.

Photoelectric Smoke and Fire Alarm

The First Alert P900 Smoke and Fire Alarm provides maximum protection and has a new sleek, slimmer design, which adds an element of style to safety. The P900 has a modern, thin square design that's less than an inch thick (half the size of a standard alarm), while still providing all the protection you need to keep what matters most safe and secure. The P900 Maximum Protection Alarm has a patented smoke entry system that allows a direct smoke path to the photoelectric sensor to detect regular and slow, smoldering fires.

Photoelectric Sensor Warns of Smoldering Fires

The First Alert P900 Smoke and Fire Alarm comes equipped with a photoelectric sensor to provide the earliest possible warning of fire. The sensor is optimized to detect larger smoke particles produced by smoldering fires, such as those caused by unextinguished cigarettes. This smoke and fire alarm also distinguishes between real threats and smoke/vapor produced during showering, cooking, and other everyday activities, helping minimize the number of false alarms. A patented smoke entry system helps ensures reliable detection by providing a direct air pathway to the sensor.

Modern, Sleek Design

Unlike older, bulkier detectors, the First Alert P900 Photoelectric Smoke Alarm features a modern, thin design that can be unobtrusively mounted on a wall or ceiling. The sleek white finish coordinates seamlessly with most home decor.

* California Residents - Please Note This Alarm is Not Compliant with California State 10 Year Sealed Battery Alarm Legislation Requirements.

Write A Review For Model # P900

Please enter your name!
Will be displayed on the comment.
Please provide valid email address!
Used for verification only.
Please choose rating!
Please enter a title for your review!
Please write a review!
Your review must be at least 25 characters.
Your review has been submitted, thank you for taking the time to write a review!

Products In This Category

0 $0.00
Top